| Directions for Use |
 |
|
 |
- When choosing diameter of the Graphite Electrodes for
electric furnace, please refer to the current carrying capacity
of the Graphite Electrodes.
- The Graphite Electrodes must be stored in clean and dry
place, avoiding shock and collision. Be sure to dry them
before use.
- When the new electrode is connected with the nipple,
it is necessary to blow out dust or dirt in the socket with
compressed air and then screw the nipple into the electrode
carefully. Please do not damage the thread.
- When connect the electrodes and the two electrodes are
close in a distance of 20-30 mm, cleaning the surface of
electrodes with compressed air. The electrode clampers should
not hold between the two security lines of the area of nipple
sockets.
- After connecting, the terminal faces of the two electrodes
should be tightly contacted.
- When the elevator of the electric arc furnace is hoisting
the electrodes, no swing is allowed so as to avoid the electrode
joints being loosened and dislocated.
- To prevent the electrodes from breaking in the furnace,
please avoid the insulation lumps.
- When charging the furnace, be sure to put the larger
lumps on the bottom and the smaller ones on the top.
|
|
|
|
|